Appliance wattage chart
Typical running watts (what it draws once going) and starting watts (the short surge when a motor or compressor kicks on) for 78 common household loads.
Ranges show the spread across models. Estimate marks values we haven't confirmed with a maker spec or our own meter yet.
Kitchen
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| Air fryer | 1,200–1,800 | same | 120 V |
| Blender | 300–1,000 | 700–1,500 | 120 V |
| Chest freezer (5-15 cu ft) Estimate | 60–120 | 400–900 | 120 V |
| Coffee maker (drip) | 800–1,200 | same | 120 V |
| Dishwasher | 1,000–2,400 | 2,000–3,000 | 120 V |
| Electric kettle Estimate | 1,200–1,500 | same | 120 V |
| Electric range (one large burner) | 1,500–3,000 | same | 240 V |
| Electric skillet | 1,000–1,500 | same | 120 V |
| Induction burner (portable) Estimate | 1,300–1,800 | same | 120 V |
| Microwave (compact, 700 W cooking power) | 800–1,150 | same | 120 V |
| Microwave (full-size, 1,000-1,200 W cooking power) | 1,000–1,800 | same | 120 V |
| Mini fridge (compact, 3-4 cu ft) Estimate | 50–100 | 250–600 | 120 V |
| Refrigerator (full-size, top or bottom freezer) | 100–250 | 600–2,900 | 120 V |
| Refrigerator (inverter compressor) Estimate | 60–180 | 100–300 | 120 V |
| Refrigerator (side-by-side or French door) Estimate | 120–300 | 800–2,900 | 120 V |
| Slow cooker Estimate | 150–300 | same | 120 V |
| Toaster (2-slice) | 800–1,200 | same | 120 V |
| Toaster oven | 1,000–1,500 | same | 120 V |
| Upright freezer Estimate | 80–180 | 500–1,200 | 120 V |
Cooling
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| Central air conditioner (3 ton) | 2,600–3,500 | 8,900–18,500 | 240 V |
| Central air conditioner (4 ton) | 3,500–4,900 | 12,500–26,200 | 240 V |
| Central air conditioner (5 ton) | 4,400–6,100 | 15,500–32,200 | 240 V |
| Dehumidifier (50 pint) Estimate | 300–700 | 700–1,400 | 120 V |
| Ductless mini-split (12,000 BTU, inverter) Estimate | 400–1,200 | 500–1,300 | 240 V |
| Portable air conditioner (10,000 BTU) Estimate | 900–1,200 | 2,200–3,000 | 120 V |
| RV rooftop air conditioner (13,500 or 15,000 BTU) Estimate | 1,200–2,150 | 2,000–3,500 | 120 V |
| Window air conditioner (12,000 BTU) | 750–1,300 | 2,200–3,300 | 120 V |
| Window air conditioner (5,000 BTU) Estimate | 350–550 | 900–1,400 | 120 V |
| Window air conditioner (8,000 BTU) Estimate | 500–850 | 1,400–2,200 | 120 V |
Heating
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| Electric blanket (queen or king) Estimate | 60–200 | same | 120 V |
| Gas boiler (circulator pump and controls) Estimate | 80–250 | 250–600 | 120 V |
| Gas furnace blower (1/3-1/2 HP, standard motor) | 300–800 | 1,000–2,100 | 120 V |
| Gas furnace blower (variable-speed ECM motor) Estimate | 100–500 | 150–600 | 120 V |
| Heat pump (3 ton, heating, whole system) | 2,100–3,800 | 9,000–20,100 | 240 V |
| Heat pump (4 ton, heating, whole system) | 3,100–4,600 | 15,000–29,800 | 240 V |
| Heat pump backup heat strips (10 kW) | 5,000–15,000 | same | 240 V |
| Heated throw Estimate | 40–120 | same | 120 V |
| Pellet stove Estimate | 80–150 | 300–500 | 120 V |
| Space heater (1,500 W) | 750–1,500 | same | 120 V |
Water and pumps
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| Sump pump (1/2 HP) | 900–1,200 | 2,100–3,250 | 120 V |
| Sump pump (1/3 HP) | 600–900 | 1,600–2,400 | 120 V |
| Sump pump (3/4 HP) Estimate | 1,100–1,500 | 3,000–4,500 | 120 V |
| Water heater (electric, 40-50 gal) | 3,800–5,500 | same | 240 V |
| Well pump (1 HP, 240 V submersible) Estimate | 1,500–2,400 | 4,000–8,000 | 240 V |
| Well pump (1/2 HP, 240 V submersible) | 670–960 | 2,100–7,700 | 240 V |
| Well pump (1/3 HP, 120 V) | 750–1,000 | 2,100–3,000 | 120 V |
Medical
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| BiPAP / BPAP (humidifier on) EstimateMedical | 30–90 | same | 120 V |
| CPAP (heated humidifier and tube on) Medical | 40–75 | same | 120 V |
| CPAP (humidifier off) EstimateMedical | 10–30 | same | 120 V |
| Oxygen concentrator (home, 5 LPM) Medical | 110–350 | 300–700 | 120 V |
Electronics
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| Desktop computer and monitor Estimate | 80–500 | same | 120 V |
| Game console Estimate | 70–220 | same | 120 V |
| Laptop | 30–100 | same | 120 V |
| TV (LED, 40-55 in.) | 50–150 | same | 120 V |
Internet and phones
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| Cable modem or fiber terminal (ONT) Estimate | 5–15 | same | 120 V |
| Phone charging | 5–30 | same | 120 V |
| Starlink (Standard kit) | 75–100 | same | 120 V |
| Starlink Mini | 20–40 | same | 120 V |
| Weather radio Estimate | 2–10 | same | 120 V |
| Wi-Fi router Estimate | 6–20 | same | 120 V |
Lighting
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| Incandescent bulb (60 W) | 40–100 | same | 120 V |
| LED bulb (60 W equivalent) | 5–15 | same | 120 V |
| LED work light | 30–150 | same | 120 V |
Laundry
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| Clothes dryer (electric, 240 V) Estimate | 1,800–5,600 | 3,000–7,000 | 240 V |
| Clothes dryer (gas, 120 V motor) Estimate | 300–1,000 | 1,200–2,500 | 120 V |
| Washing machine | 350–800 | 1,200–2,000 | 120 V |
Tools
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| Air compressor (1 HP, pancake or hot-dog) Estimate | 1,200–1,800 | 3,500–5,000 | 120 V |
| Circular saw (7-1/4 in.) | 1,200–1,500 | 2,000–3,500 | 120 V |
| Drill (corded) | 400–800 | 600–1,200 | 120 V |
Comfort
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| Aquarium (heater, filter, air pump) Estimate | 30–300 | same | 120 V |
| Box fan (20 in.) Estimate | 40–100 | 80–200 | 120 V |
| Ceiling fan Estimate | 15–80 | 30–120 | 120 V |
| Hair dryer Estimate | 1,000–1,875 | same | 120 V |
| Rechargeable or USB fan Estimate | 2–10 | same | 120 V |
Outdoor
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| Garage door opener (1/2 HP) Estimate | 400–875 | 1,000–2,000 | 120 V |
| Pressure washer (electric) Estimate | 1,200–1,800 | 2,000–3,500 | 120 V |
Vehicle
| Appliance | Running W | Starting W | Volts |
|---|---|---|---|
| 12 V compressor cooler / fridge | 35–70 | 50–120 | 12 V DC |
| EV charger (Level 2, 240 V) | 3,300–11,500 | same | 240 V |