Sump Pump Backup Calculator
Pick your pump and how hard it's raining. See how long a battery backup pump, a power station or a generator keeps the basement dry, and what each costs.
A second, 12-volt pump sits in the pit above your main pump and runs from its own battery when the power or the main pump fails.
Maker's claim: 48 hours at 10% pumping with one BW-27AGM. We count on 80% of that, scaled to your pump's duty.
Covers your 24-hour outage on one charge.
Show the math
- Continuous pumping on one charge: maker’s claim 48 h × 10% pumping (BW-27AGM) = 4.8 h
- Hours we count on: 4.8 h × 0.8 = 3.84 h
- Your pump duty: 10 starts an hour × 15 s ÷ 3,600 s = 0.0417
- Hours of protection: 3.84 h ÷ 0.0417 = 92.2 h
Assumptions used: Share of a sump backup claim we count on. What these mean
Side by side for your 24-hour outage
| Battery backup pump | Power station | Generator | |
|---|---|---|---|
| Protection | 92 hours (about 3.8 days) | 18.5 hours | 11.5 hours a tank, then refuel |
| Covers the outage? | Yes | No | Yes, if someone refuels it |
| Works when you're away? | Yes | Yes (UPS mode) | No |
| Also protects if the main pump fails? | Yes | No | No |
| Upfront cost | About $350–$950 for pump, controller and battery, plus installation | About $559 | About $1,199 plus a cord |
Prices are the brands' own list prices when we checked; stores may differ.
How this is calculated
How often your pump runs
A sump pump runs in short bursts. Its duty is the share of time it's actually pumping: starts an hour × seconds per run ÷ 3,600. Ten 15-second runs an hour is a duty of about 4%. Light rain is about 4 starts an hour, moderate 10, heavy 20. If you time your own pump during a storm, use the "I timed my pump" option; it beats any default.
Battery backup pump
Makers rarely publish their backup pump's amp draw, but they do publish a runtime claim such as "48 hours at a 10% duty cycle." That claim fixes how long the battery can pump without stopping: 48 × 0.10 = 4.8 hours. We count on 80% of that, because the claim assumes a new, fully charged battery, then divide by your pump's duty. If you choose "another system," we use the battery's amp-hours, an 80% emergency depth of discharge and a Peukert correction for lead-acid batteries, which deliver less at high current.
Power station
First the starting check: a ⅓ HP pump draws about 800 W running but 1,600–2,400 W for a moment as the motor starts, and the station's surge rating has to cover that. Then runtime = 95% of the rated capacity ÷ (average pump watts ÷ 0.90 inverter efficiency + the inverter's idle draw). For a pump, the idle draw is often a big share of the total, because the inverter stays on all day while the pump runs a few minutes an hour.
Generator
Size = the pump's running watts ÷ 0.80 (so it isn't run flat out for hours) and its full starting watts. Fuel comes from the maker's runtime claims where they exist. A generator burns fuel all day while the pump only needs it a few minutes an hour, so most of the fuel goes to idling.
Full formulas and default assumptions: How the math works.
Related guides
- Outage Plan Builder (the sump pump plus everything else you need to keep running)
- Sump pump backup: battery vs generator vs power station
- What size generator do you need for a sump pump?
- How much does a battery backup sump pump cost?