Sump Pump Backup Calculator

Pick your pump and how hard it's raining. See how long a battery backup pump, a power station or a generator keeps the basement dry, and what each costs.

Your pump and your storm

The horsepower is on the pump's label or in its manual.

Your pump runs about 4.2% of the time in these conditions.

A second, 12-volt pump sits in the pit above your main pump and runs from its own battery when the power or the main pump fails.

Hours of protection92 hours (about 3.8 days)Range 46 hours to 138 hours (about 5.7 days), depending on how long each run lasts

Maker's claim: 48 hours at 10% pumping with one BW-27AGM. We count on 80% of that, scaled to your pump's duty.

Covers your 24-hour outage on one charge.

Show the math
  1. Continuous pumping on one charge: maker’s claim 48 h × 10% pumping (BW-27AGM) = 4.8 h
  2. Hours we count on: 4.8 h × 0.8 = 3.84 h
  3. Your pump duty: 10 starts an hour × 15 s ÷ 3,600 s = 0.0417
  4. Hours of protection: 3.84 h ÷ 0.0417 = 92.2 h

Assumptions used: Share of a sump backup claim we count on. What these mean

Side by side for your 24-hour outage

Battery backup pumpPower stationGenerator
Protection92 hours (about 3.8 days)18.5 hours11.5 hours a tank, then refuel
Covers the outage?YesNoYes, if someone refuels it
Works when you're away?YesYes (UPS mode)No
Also protects if the main pump fails?YesNoNo
Upfront costAbout $350–$950 for pump, controller and battery, plus installationAbout $559About $1,199 plus a cord

Prices are the brands' own list prices when we checked; stores may differ.

How this is calculated

How often your pump runs

A sump pump runs in short bursts. Its duty is the share of time it's actually pumping: starts an hour × seconds per run ÷ 3,600. Ten 15-second runs an hour is a duty of about 4%. Light rain is about 4 starts an hour, moderate 10, heavy 20. If you time your own pump during a storm, use the "I timed my pump" option; it beats any default.

Battery backup pump

Makers rarely publish their backup pump's amp draw, but they do publish a runtime claim such as "48 hours at a 10% duty cycle." That claim fixes how long the battery can pump without stopping: 48 × 0.10 = 4.8 hours. We count on 80% of that, because the claim assumes a new, fully charged battery, then divide by your pump's duty. If you choose "another system," we use the battery's amp-hours, an 80% emergency depth of discharge and a Peukert correction for lead-acid batteries, which deliver less at high current.

Power station

First the starting check: a ⅓ HP pump draws about 800 W running but 1,600–2,400 W for a moment as the motor starts, and the station's surge rating has to cover that. Then runtime = 95% of the rated capacity ÷ (average pump watts ÷ 0.90 inverter efficiency + the inverter's idle draw). For a pump, the idle draw is often a big share of the total, because the inverter stays on all day while the pump runs a few minutes an hour.

Generator

Size = the pump's running watts ÷ 0.80 (so it isn't run flat out for hours) and its full starting watts. Fuel comes from the maker's runtime claims where they exist. A generator burns fuel all day while the pump only needs it a few minutes an hour, so most of the fuel goes to idling.

Full formulas and default assumptions: How the math works.