Generator Safety: Carbon Monoxide, Rain, Cords and Transfer Switches

How far a generator must be from the house, why never in the garage, running in rain, extension cords, refueling, and why you must never back-feed.

Updated

A generator keeps the fridge and the sump pump going, but used the wrong way it kills people every year. The CPSC calls portable generators “one of the leading causes of post-storm carbon monoxide deaths”: an average of nearly 100 people in the US die each year from carbon monoxide from portable generators. Nearly all of those deaths are preventable with a few rules:

  1. Outdoors only, at least 20 feet from the house, exhaust pointed away from windows, doors and vents.
  2. Never in a garage, basement, shed or crawl space, even with the doors open.
  3. Carbon monoxide alarms inside, battery-powered or with battery backup, on every level.
  4. Never plug it into a wall outlet. Use extension cords, or a transfer switch installed by an electrician.
  5. Keep it dry, and let it cool before refueling.

The rest of this page explains each one, with the official sources at the end.

Carbon monoxide: why the distance matters

A gasoline or propane generator’s exhaust is full of carbon monoxide (CO), a gas you can’t see or smell. A CPSC public service message puts it bluntly: one portable generator produces as much CO as hundreds of cars. Indoors, or close to an open window, it can build to a deadly level within minutes.

  • How far from the house? The CDC says more than 20 feet from windows, doors and vents; CPSC and Ready.gov say at least 20 feet from the house. Treat 20 feet as the minimum, not the target.
  • Point the exhaust away from the house and from your neighbors’ windows too.
  • Watch the wind. A breeze can push exhaust back toward the house, so a CO alarm indoors is not optional.
  • Never run it in an enclosed or partly enclosed space: the house, an attached or detached garage, a basement, a crawl space, a shed, a porch with walls, or under a deck. Open doors and fans don’t make it safe.

CO alarms

CPSC’s advice: working CO alarms, battery-operated or with battery backup, on every level of the home and outside sleeping areas. Interconnected alarms are best, because when one sounds they all do. Test them monthly, and before storm season. Plug-in alarms without a battery stop working in an outage, which is exactly when you need them.

Choose a generator with a CO shutoff

Newer portable generators can sense CO building up around them and shut themselves off. CPSC recommends looking for one, and names two standards: models certified to PGMA G300-2023 or UL 2201-2023 include CO safety technology, and UL 2201 models also give off less CO in the first place.

In our product data, every Honda, Generac and Westinghouse inverter generator lists a CO shutoff; the Westinghouse WGen3600 and WGen5300 conventional models don’t. A shutoff is a backstop, not permission to run the generator closer to the house.

Never back-feed your house

Plugging a generator into a wall outlet, with a “suicide cord” that has a plug on both ends, or into a dryer outlet, is called back-feeding. It’s dangerous in three ways:

  • It can electrocute line workers. Power flows out through your main panel to the utility transformer, which steps it up to thousands of volts on lines the crew thinks are dead. CPSC warns it also endangers neighbors on the same transformer.
  • It can start a fire. The cord and outlet aren’t built for the whole house’s current, and nothing protects them.
  • It can damage the generator and your wiring when grid power comes back on.

To power circuits in your home, have a licensed electrician install a transfer switch or a breaker interlock, with the right permit. Either one keeps your house disconnected from the grid while the generator runs. OSHA notes that a generator feeding a building through a transfer switch must be connected to a grounding electrode, such as a ground rod; your electrician handles that as part of the install.

Generators with a 240 V outlet, such as an L14-30 twist-lock or a 14-50, can feed a transfer switch or interlock through an inlet box. Smaller inverter generators with only household outlets can still run appliances on extension cords.

Extension cords

Without a transfer switch, run each appliance on its own extension cord, plugged straight into the generator. Ready.gov says to use heavy-duty extension cords; in practice:

  • Outdoor-rated and three-prong, with no cuts, cracks or missing ground pin.
  • Rated for the load. The cord’s label gives its amps or watts; it must be more than what you plug into it. Longer runs need a heavier cord (a lower gauge number). A thin cord on a fridge or sump pump overheats, and the voltage drop makes motors run hot and struggle to start.
  • Routed safely: not under rugs, not pinched in doors or windows, and out of standing water.
  • One appliance per cord for big loads. Power strips and daisy-chained cords are where cords overheat.

Rain, snow and wet ground

Ready.gov: keep the generator dry and protected from rain or flooding, because touching a wet generator or anything plugged into it can cause an electric shock. CPSC adds: follow the maker’s instructions for wet weather.

  • Run it under a cover or canopy made for running generators. It must stay open on the sides for airflow, and the generator still has to be 20 feet from the house. A tarp, tent or carport against the house is not a safe substitute.
  • Set it on dry, level ground, never in standing water.
  • Dry your hands before touching it, and keep cord connections off the ground and out of puddles.
  • In snow, clear around it so the exhaust and air intake stay open.

Refueling and fuel storage

  • Turn it off and let it cool before refueling. Ready.gov: fuel spilled on hot engine parts can ignite.
  • Store fuel in approved containers, outside the house and away from any flame or heat source, including the generator’s own exhaust.
  • Plan refills before dark. Small inverter generators often need refueling every 8 to 20 hours; our Generator Size & Fuel Calculator shows how often yours will.
  • Propane tanks stay outdoors too. Below about 20 °F a 20-lb tank may not supply propane fast enough for a large generator.

Before the next outage

  • Read the manual and the labels on the generator, and start it every few months as the manual says, so it starts when you need it.
  • Check for recalls at cpsc.gov/Recalls. In April 2026, for example, Generac recalled about 149,000 portable generators from several GP-series lines, sold May 2025 to February 2026, because fuel can leak from the carburetor the first time they’re filled. Generac’s recall page checks your serial number.
  • Pick the spot now: a place 20 feet or more from the house, ideally sheltered from rain, with a route for the cords that doesn’t pass through a window.
  • Test your CO alarms and keep spare batteries.
  • Size it right so you aren’t tempted to overload it: see running vs starting watts.

Our safety and medical notes cover the rest of backup power safety: batteries, sump pumps in flooded basements, and medical devices.

Sources

Questions people ask

How far should a generator be from the house?

At least 20 feet from the house and any building, with the exhaust pointed away from windows, doors and vents. That's the minimum the CDC, CPSC and Ready.gov give. Farther is better, and wind can still carry exhaust inside, so keep a carbon monoxide alarm running indoors.

Can I run a generator in the garage with the door open?

No. Never run a generator in a garage, basement, crawl space, shed or any enclosed space, even with doors and windows open. Carbon monoxide builds up fast and can kill within minutes.

Can I run a generator in the rain?

Only if it's kept dry: under a cover or canopy made for running generators, outdoors and still 20 feet from the house. Follow the maker's instructions for wet weather. Touching a wet generator or anything plugged into one can cause an electric shock.

Can I plug a generator into a wall outlet to power my house?

No. That's back-feeding, and it can send power down the utility lines and electrocute line workers or neighbors, as well as start a fire in your wiring. To power home circuits, have a licensed electrician install a transfer switch or interlock.

What is a CO shutoff on a generator?

A sensor that turns the generator off when carbon monoxide builds up nearby. CPSC recommends looking for one and names two standards, PGMA G300-2023 and UL 2201-2023. UL 2201 models also produce less carbon monoxide to begin with.