Battery Backup for a CPAP: How Many Nights, and What Size to Buy

How long a power station or 12 V battery runs a CPAP in an outage, with the humidifier on or off, AC vs the DC cable, and the battery size to buy.

Updated

How we make money: some links on this page go to stores that may pay us a commission if you buy. It doesn't change the price you pay or which product we recommend; we rank by fit first. Details

The short answer: a 1,000 Wh power station runs a CPAP for about 1.5 nights with the heated humidifier on, and about 3.8 nights with it off. Plug in the machine’s DC cable instead of the AC outlet and those numbers rise to about 1.9 and 7.2 nights. For a medical device we suggest buying for twice the nights you expect, so for a 3-night outage with the humidifier on, look for about 4,000 Wh on the DC cable.

These are estimates for 8 hours a night. Your machine, pressure setting and room change them, so work out your own in the CPAP Battery Backup Calculator.

How many watts a CPAP uses

The heated humidifier and heated tube use most of the power. The machine’s blower on its own is small.

Machine and settingTypical drawRangeEnergy for an 8-hour night
CPAP, humidifier and heated tube off Estimate15 W10–30 Wabout 120 Wh
CPAP, humidifier and heated tube on56 W40–75 Wabout 450 Wh
BiPAP / bilevel, humidifier on Estimate60 W30–90 Wabout 480 Wh

The “humidifier on” figure is ResMed’s published figure for the AirSense 11 as listed by a medical supplier (56 W typical, 73 W peak). The humidifier-off and BiPAP figures are our estimates from typical ratings, not measurements, and they’re marked as estimates in our appliance wattage chart. If you can, measure your own machine with a plug-in watt meter for a night: the energy figure it shows is the most useful number you can have.

Don’t size from the power brick. Its label is the most it can deliver, not what the machine draws through the night.

How long a power station runs a CPAP

Approximate nights of 8 hours, from our sizing library, assuming you switch the station off during the day. “On” and “off” are the heated humidifier and tube; “DC” is the machine maker’s DC cable:

Power stationOn, ACOn, DCOff, ACOff, DC
Jackery Explorer 300 v2, 288 Wh0.50.51.52
BLUETTI AC70, 768 Wh1.21.43.45.4
Jackery Explorer 1000 v2, 1,024 Wh1.51.93.87.2
Anker SOLIX C1000 Gen 2, 1,024 Wh1.41.93.37.2
Jackery Explorer 2000 v2, 2,042 Wh2.83.86.214.5
EcoFlow DELTA 3 Ultra, 3,072 Wh3.75.86.921.8

Each figure is rounded down. A hungrier or thriftier machine moves the real number a lot: the Explorer 1000 v2 with the humidifier on could give anywhere from about 1.2 to 2 nights on AC, and with the humidifier off on DC, from about 3.6 to 10.9 nights.

Two things stand out:

  • The humidifier off is the biggest saving, often 2 to 4 times as many nights. Dry air bothers some people, so ask your provider before you plan around it.
  • The DC cable matters most on big stations. The two 1,024 Wh stations above hold the same energy, but on AC the Anker gives a little less because its larger inverter (2,000 W vs 1,500 W) uses more power just to stay on. On DC the inverter is off and they come out the same.

AC outlet or the DC cable?

Through the AC outlet, the station turns battery power into 120 V AC and the CPAP’s power brick turns it back into DC. That costs about 10% in the inverter, plus the few watts the inverter burns just by being on: about 15 W on a 1,500 W station. For a 15 W CPAP, the inverter’s idle draw is as big as the machine.

A DC cable or converter from your machine’s maker plugs into the station’s 12 V car port and skips the inverter. We count about a 10% loss in the cable. Ask the maker which one fits your model; don’t use a generic adapter.

The AC outlet still has one advantage: a station with UPS mode can sit between the wall and your CPAP and take over within a few hundredths of a second when the power goes out, so the machine keeps running while you sleep. Every station in the table above has UPS mode in our data, with a 10 to 20 ms switchover. A common plan: run on UPS through the first night, then switch to the DC cable once you know the outage is a long one.

What size to buy

For a medical device we plan for twice the nights you expect, plus a 25% margin. Outages run longer than forecast, batteries lose capacity with age, and a cold room or a higher pressure setting raises the draw.

capacity to look for = nights × 2 × energy a night × 1.25 ÷ 0.95 usable

NightsOn, ACOn, DCOff, ACOff, DC
11,700 Wh1,400 Wh700 Wh400 Wh
23,300 Wh2,700 Wh1,400 Wh800 Wh
34,900 Wh4,000 Wh2,000 Wh1,100 Wh
58,200 Wh6,600 Wh3,400 Wh1,800 Wh

Rated Wh to look for, for a typical CPAP at 8 hours a night, and a station with a 1,500 W inverter for the AC columns. A station with a bigger inverter needs a bit more on AC.

So for a typical 3-day outage:

  • Humidifier off, DC cable: a station of about 1,100 Wh or more covers it.
  • Humidifier on, DC cable: you’re into big stations, around 4,000 Wh, or a 2,000 Wh station with an expansion battery.
  • Humidifier on, AC only: around 4,900 Wh. This is where recharging (below) starts to make more sense than buying a bigger battery.

A 12 V battery instead

A 12 V deep-cycle battery and your machine’s DC cable is a common, cheaper setup, especially for camping. You’ll need a fused 12 V socket or a battery box made for the purpose; the CPAP’s DC cable won’t clip onto bare battery terminals.

12 V 100 Ah batteryHumidifier on, DCHumidifier off, DC
LiFePO4 (lithium), 12.8 Vabout 2.3 nightsabout 8.6 nights
AGM (sealed lead-acid), 12 Vabout 1.9 nightsabout 7.2 nights

We count on 90% of a LiFePO4 battery and 80% of an AGM. Draining lead-acid that far is fine in an emergency but wears it out quickly if you do it often. For 3 nights on the DC cable with the humidifier off, look for a LiFePO4 battery of about 90 Ah; with the humidifier on, about 330 Ah. To turn a battery’s Ah into watt-hours (or a station’s Wh into Ah), use the amp hours to watt hours calculator.

When the outage runs long

  • Solar panels can top up a station during the day. A 200 W panel set puts back about 700 Wh on a day with 4.5 hours of full sun, which covers a night or more with the humidifier off. Cloudy days give much less. The Power Station Runtime Calculator has a solar “what if”.
  • A car can recharge a station from its 12 V socket while you drive, slowly.
  • A generator can recharge the station during the day. Run it outdoors only, well away from the house; never in a garage. See our safety notes.

Before the next outage

  1. Talk to your provider and your machine’s maker about running on battery, and about the humidifier.
  2. Register with your utility’s medical-needs program. It won’t guarantee your power stays on, but it can mean earlier warnings and checks.
  3. Get the maker’s DC cable or converter and keep it with the battery.
  4. Charge the station every few months, and test it for a night once a year.
  5. Have a plan that doesn’t need a battery, such as somewhere to go that has power, for an outage that outlasts everything above.

Work out your own machine, setting and source in the CPAP Battery Backup Calculator. To run your CPAP alongside a phone, lights or a fridge, use the Power Station Runtime Calculator.

Products in this guide

Jackery Explorer 1000 v2

Capacity
1,024 Wh
Output
1,500 W (surge 3,000 W)
Battery
LiFePO4
UPS mode
Yes, 20 ms switchover
Weight
23.8 lb
Check price at Jackery

Usually about $559 on the Jackery site. Specs checked Nov 17, 2026.

Anker SOLIX C1000 Gen 2

Capacity
1,024 Wh
Output
2,000 W (surge 3,000 W)
Battery
LiFePO4
UPS mode
Yes, 10 ms switchover
Check price at Anker SOLIX

Usually about $530 on the Anker SOLIX site. Specs checked Nov 20, 2026.

Jackery Explorer 2000 v2

Capacity
2,042 Wh
Output
2,200 W (surge 4,400 W)
Battery
LiFePO4
UPS mode
Yes, 20 ms switchover
Weight
39.5 lb
Check price at Jackery

Usually about $999 on the Jackery site. Specs checked Nov 17, 2026.

EcoFlow DELTA 3 Ultra

Capacity
3,072 Wh
Output
3,600 W (surge 7,200 W)
Battery
LiFePO4
UPS mode
Yes, 10 ms switchover
Weight
74.3 lb
Check price at EcoFlow

Usually about $1,369 on the EcoFlow site. Specs checked Nov 19, 2026.

Questions people ask

How many watts does a CPAP use?

About 10 to 30 W with the heated humidifier and tube off, and about 40 to 75 W with them on. ResMed's published figures for the AirSense 11 are 56 W typical and 73 W peak with the humidifier. The rating on the power brick is the maximum, not what it draws through the night.

How long will a 1,000 Wh power station run a CPAP?

About 1.5 nights of 8 hours with the heated humidifier on, through the AC outlet. With the maker's DC cable it's about 1.9 nights. With the humidifier off, it's about 3.8 nights on AC and about 7.2 on DC. These are estimates; your machine and pressure setting change them.

How long will a 100Ah battery run a CPAP?

A 12 V 100 Ah LiFePO4 battery on the DC cable runs a CPAP about 2.3 nights with the humidifier on and about 8.6 nights with it off. A 100 Ah AGM battery gives less, about 1.9 and 7.2 nights, because you should only use about 80% of it.

Do CPAP machines have a battery backup?

Most home CPAP machines have no built-in battery; they stop when the power goes out. Some makers sell optional battery packs or DC cables. A power station with UPS mode can keep the machine running when the power drops.

Can I use a computer UPS for my CPAP?

Only for a short gap. A computer UPS is built to give you a few minutes to shut a PC down, not a night of runtime, and many budget models put out a stepped sine wave rather than the pure sine wave a CPAP is designed for. Check the UPS maker's runtime chart for your machine's watts.