The short answer: a gas furnace with a standard blower draws about 500 W while the blower runs (about 1,400 W for a moment when it starts), and in winter it runs about half the time. A 1,000 Wh power station keeps it going for about 3 hours; a 2,000 Wh station about 6 hours. For a multi-day winter outage, a small inverter generator is the practical choice: it runs a furnace on about 2 gallons of gas a day.
A gas furnace burns gas for heat, but it can’t run without electricity: the blower, the draft inducer, the igniter and the control board all need power.
How many watts a furnace uses
Typical values from our appliance wattage chart:
| Heating system | Running | Starting | Average in winter | Energy a day |
|---|---|---|---|---|
| Gas furnace, standard (PSC) blower | 500 W (300–800) | 1,400 W | 250 W | 6 kWh |
| Same, in very cold weather (runs 80% of the time) | 500 W | 1,400 W | 400 W | 9.6 kWh |
| Gas furnace, variable-speed (ECM) blower Estimate | 250 W (100–500) | 300 W | 150 W | 3.6 kWh |
| Gas boiler (circulator pump and controls) Estimate | 150 W (80–250) | 400 W | 75 W | 1.8 kWh |
| Pellet stove (auger and fans) Estimate | 100 W, igniter 300–500 W | 500 W | 100 W | 2.4 kWh |
The averages assume the furnace runs 50% of the time (60% for the variable-speed one, which runs longer at lower speed); in a cold snap it runs much more. Rows marked Estimate are our own estimates from typical ratings. Your furnace’s rating plate gives its amps: amps × 120 is roughly the most it draws.
Not sure which blower you have? Variable-speed blowers are common on high-efficiency furnaces; the manual or the model number will say “ECM” or “variable speed”.
How long a power station runs a furnace
Hours of heat, from our sizing library:
| Power station | Standard blower | Standard, very cold | Variable-speed blower | Boiler |
|---|---|---|---|---|
| Jackery Explorer 300 v2, 288 Wh | can’t run it | can’t run it | 1.5 h | 3 h |
| BLUETTI AC70, 768 Wh | 2.5 h | 1.6 h | 4 h | 7.5 h |
| Jackery Explorer 1000 v2, 1,024 Wh | 3 h | 2 h | 5 h | 9.5 h |
| Jackery Explorer 2000 v2, 2,042 Wh | 6 h | 4 h | 10 h | 18 h |
| EcoFlow DELTA 3 Ultra, 3,072 Wh | 9 h | 6 h | 14 h | 24 h |
| Anker SOLIX F3800 Plus, 3,840 Wh | 10.5 h | 7 h | 16 h | 25 h |
| Jackery Explorer 5000 Plus, 5,040 Wh | 13.5 h | 9 h | 20 h | 30.5 h |
Rounded down. With the fridge on the same station, a standard furnace and fridge together run about 2.5 hours on a 1,000 Wh station and 5 hours on a 2,000 Wh one.
For a full day of heat with a standard blower you’d need about 9,300 Wh (5,800 Wh with a variable-speed blower), including a 25% margin, on a station with a 1,500 W inverter. That’s a whole-home battery or a big station with several expansion batteries. So for a furnace, a power station is best for:
- Short outages, a few hours to an evening.
- Keeping the house above freezing overnight by turning the thermostat down.
- Pairing with a generator: run the generator during the day for the furnace and to recharge the station, and let the quiet station carry the furnace for a few hours at night.
A generator for the furnace
| Load | Generator size needed | Honda EU2200i (inverter) | Westinghouse iGen2800 (inverter) |
|---|---|---|---|
| Standard furnace | 650 running / 1,400 starting W | 2.2 gal/day | 1.6 gal/day |
| Standard furnace, very cold | 650 / 1,400 W | 2.7 gal/day | 1.9 gal/day |
| Variable-speed furnace | 350 / 350 W | 2 gal/day | 1.6 gal/day |
| Standard furnace + fridge | 850 / 1,550 W | 2.4 gal/day | 1.8 gal/day |
Gas a day running 24 hours. Any 2,000 W-class inverter generator covers a furnace and fridge. Add a sump pump and you need more starting watts; see what a 2,000 or 3,500 W generator can run.
Use an inverter generator or a power station for a furnace. Modern furnace control boards, especially on variable-speed furnaces, are sensitive to rough power from some conventional generators.
Connecting a hardwired furnace
Most furnaces are wired straight into the house, with no plug to move. Your options:
- A transfer switch or breaker interlock for the whole panel, installed by a licensed electrician. You then switch on the furnace circuit along with the others you need.
- A transfer switch for just the furnace circuit, also installed by an electrician. It lets you plug the furnace into a generator or power station with a cord, and keeps it disconnected from the grid while you do.
- Never back-feed the house through a wall or dryer outlet. It can electrocute line workers and start fires. See our generator safety guide.
If the furnace’s fan runs on backup power but the burner won’t light, the cause can be how the generator or station handles its neutral and ground wiring. Ask the electrician who installs the switch to check this; don’t modify the wiring yourself.
Stretching your heat
For every heating type, a plan by outage length and keeping pipes from freezing, see how to keep heat on in a winter power outage.
- Turn the thermostat down to 60 °F or so. The furnace runs less, and the battery or tank lasts longer.
- Heat one room: close doors and vents to rooms you aren’t using, and gather in one space.
- Use electric blankets at night instead of more furnace time: about 150 W, cycling. See can a power station run a space heater? for how they compare.
- Keep pipes from freezing: if the heat will be off for long in deep cold, drip faucets and open cabinet doors on outside walls.
Work out your own furnace, fridge and other loads in the Power Station Runtime Calculator or the Generator Size & Fuel Calculator.
Source for the vent and CO alarm advice: CPSC, Winter weather safety tips (March 2026).
Products in this guide
Jackery Explorer 2000 v2
- Capacity
- 2,042 Wh
- Output
- 2,200 W (surge 4,400 W)
- Battery
- LiFePO4
- UPS mode
- Yes, 20 ms switchover
- Weight
- 39.5 lb
Usually about $999 on the Jackery site. Specs checked Nov 17, 2026.
EcoFlow DELTA 3 Ultra
- Capacity
- 3,072 Wh
- Output
- 3,600 W (surge 7,200 W)
- Battery
- LiFePO4
- UPS mode
- Yes, 10 ms switchover
- Weight
- 74.3 lb
Usually about $1,369 on the EcoFlow site. Specs checked Nov 19, 2026.
Honda EU2200i
- Running / starting
- 1,800 / 2,200 W (gasoline)
- Type
- Inverter (clean power)
- Fuels
- gasoline
- CO shutoff
- Yes
- Weight
- 47.4 lb
Usually about $1,199 on the Honda site. Specs checked Nov 17, 2026.
Westinghouse iGen2800DFc
- Running / starting
- 2,200 / 2,800 W (gasoline)
- Type
- Inverter (clean power)
- Fuels
- gasoline, propane
- CO shutoff
- Yes
- Weight
- 45 lb
Usually about $599 on the Westinghouse site. Specs checked Nov 17, 2026.
Questions people ask
How many watts does a gas furnace use?
A furnace with a standard (PSC) blower motor draws about 300 to 800 W while the blower runs, typically about 500 W, and around 1,400 W for a moment when it starts. A furnace with a variable-speed (ECM) blower draws about 100 to 500 W and barely surges.
How long will a power station run a gas furnace?
A 1,000 Wh station runs a furnace with a standard blower for about 3 hours when the blower runs half the time, and about 2 hours in very cold weather. A variable-speed furnace lasts about 5 hours. A 2,000 Wh station roughly doubles those times.
What size generator do I need to run a gas furnace?
About 650 running and 1,400 starting watts for a standard furnace, or 850 running and 1,550 starting with a fridge too. A 2,000 W-class inverter generator such as the Honda EU2200i covers that and uses about 2.2 to 2.4 gallons of gas a day.
Can I plug my furnace into a generator?
Most furnaces are hardwired, so there's no plug. An electrician can install a transfer switch or interlock for the house, or a transfer switch for just the furnace circuit. Never back-feed the house through an outlet.
Will a furnace run on a power station?
Yes, if the station's output covers the blower's running and starting watts and it's connected through a proper transfer switch or inlet. Power stations give clean power, which modern furnace control boards need. The battery is the limit: a standard furnace empties a 1,000 Wh station in about 3 hours.