How to Keep Heat On in a Winter Power Outage

What a furnace, boiler, heat pump or electric heat needs to run in a winter outage, how to stay warm safely, and how to keep pipes from freezing.

Updated

The short answer: almost every central heating system needs electricity, but most need far less than you’d think. A gas furnace, a boiler or a pellet stove only needs power for its fan, pump and controls: a power station can carry it for hours and a small generator for days. Heat pumps and electric heat are the hard case. They make heat from electricity, so keeping them on means a standby generator or a whole-home battery. Without one, the plan is to heat one room and keep people and pipes warm.

Start with what heats your home, then pick a plan for the length of outage you expect.

What each heating system needs

Watts and energy for each system on its own, from our sizing library and appliance data:

Heating systemRunningStartingEnergy a dayGenerator sizeOn a 1,024 Wh station
Gas or propane furnace, standard blower500 W1,400 W6 kWh650 W / 1,400 W3 hours
Gas or propane furnace, variable-speed blower *250 W300 W3.6 kWh350 W / 350 W5 hours
Gas boiler (radiators or floor heat) *150 W400 W1.8 kWh200 W / 400 W9.5 hours
Pellet stove *100 W500 W2.4 kWh150 W / 500 W7.5 hours
Heat pump, 3 ton, no backup strips (outdoor unit and indoor blower), 240 V2,500 W15,000 W36 kWh3,150 W / 15,000 Wneeds 240 V
Heat pump with 10 kW backup strips on, 240 V12,500 W25,000 W108 kWh15,650 W / 25,000 Wneeds 240 V
Electric baseboard or space heater, one 1,500 W room1,500 W1,500 W18 kWh1,900 W / 1,900 W1.1 hours

Generator size is running / starting watts to look for, with 20% headroom. Energy a day assumes the system runs about half the time (a cold snap means more); the station column is the Jackery Explorer 1000 v2, rounded down. Rows marked * are our estimates; your equipment’s rating plate gives its real amps.

What the table says:

  • Gas or propane furnace: a small load. A 2,000 W-class inverter generator runs it easily; a power station covers an evening or a night with the thermostat turned down. Details, runtimes on seven stations and hookup options are in battery backup for a gas furnace.
  • Boiler: the smallest load of all (a circulator pump and controls), and boiler controls are sensitive, so use an inverter generator or a power station for clean power.
  • Pellet stove: small once running, but the igniter needs a few hundred watts for several minutes at start-up. Keep it running rather than relighting it.
  • Heat pump: about 2,500 W running but a start surge near 15,000 W, and it needs 240 V. No portable generator in our data covers that start. A soft-start kit cuts the surge a lot; ask your HVAC contractor whether one suits your unit.
  • Heat pump backup strips are the biggest load in the house: 12,500 W with 10 kW strips on. On backup power, have an electrician lock out “emergency heat” or stage the strips, or the generator or battery will trip.
  • Electric baseboard or space heaters: every 1,500 W room is a whole small generator’s worth. Batteries can’t keep up: a heater on high empties a 1,024 Wh station in about 0.5 hours. See can a power station run a space heater?

Wood stoves and gas fireplaces that need no power (vented, with a standing pilot or battery ignition) are the best backup heat there is. Check yours lights without power before winter, and keep a CO alarm in that room.

A plan for your outage

The Outage Plan Builder’s winter-storm scenario starts from the essentials below and adds your heat. Each link opens it with that list filled in, so you can edit it and compare a power station, a generator and a hybrid:

Your heatEnergy a dayRunning / startingGenerator sizeSmallest generator that fitsGas a day
Gas furnace9.3 kWh1,044 W / 1,944 W1,350 W / 1,950 WHonda EU2200i2.7 gal
Electric heat (one space heater, 8 h a day)9.3 kWh2,044 W / 2,894 W2,600 W / 2,900 WHonda EU3200i2.7 gal
Heat that needs no power (wood stove, gas fireplace)3.3 kWh544 W / 1,394 W700 W / 1,400 WHonda EU2200i2 gal

Every list includes: Fridge, 4 × LED bulb, Router, Modem, 2 × Phone, 2 × Electric blanket. Gas a day is for the generator running around the clock; running it in shifts uses less. To cover one full day on a power station alone with a gas furnace, the smallest setup in our data is a Jackery HomePower 3600 Plus + 4 extra batteries, which is why a generator (or a station recharged by one) is the usual answer for winter.

A few hours to an evening

  • Keep doors and windows shut and close curtains at dusk; a well-closed house loses only a few degrees an hour.
  • A power station can run a gas furnace or boiler for a few hours, or an electric blanket for about 9.5 hours (1.2 nights of 8 hours) on a 1,024 Wh station.
  • Charge phones and keep a battery radio for updates.

Overnight to a day

  • Pick one room, ideally on the sunny side and away from outside walls, and gather everyone in it. Close the doors to the rest of the house.
  • Turn the thermostat down to about 60 °F if a battery is running the furnace: it runs less and lasts longer.
  • Layers, hats, sleeping bags and electric blankets keep people warm with far less energy than heating air.
  • Start protecting pipes (below) if the house will drop toward freezing.

Several days

  • A generator connected through a transfer switch or interlock installed by an electrician is the practical way to keep a furnace, boiler or pellet stove running for days. Size yours with the Generator Size & Fuel Calculator and store enough fuel for the outage.
  • For a heat pump or electric heat home, a standby generator or home batteries are the only way to keep the heat on. Otherwise plan where you’ll go.
  • If you can’t keep the house safely warm, go somewhere that has power: family, friends, or a warming center. Call 211 to find one near you.

Keeping pipes from freezing

  • Let faucets drip on outside walls; moving water is slow to freeze.
  • Open cabinet doors under kitchen and bathroom sinks so room air reaches the pipes.
  • Keep the heated room’s warmth near the plumbing where you can, and close off unheated spaces.
  • For a long outage in deep cold, shut off the main water valve and drain the pipes by opening the lowest and highest faucets. Leave water heaters and boilers to a plumber.
  • If a pipe freezes, keep the faucet open and warm the pipe gently with a hair dryer, a space heater or warm towels. Never use an open flame. If a pipe bursts, shut off the main valve.

Hooking heat up to backup power

  • Furnaces and boilers are usually hardwired. An electrician can install a whole-panel transfer switch or interlock, or a single-circuit switch for just the furnace, so you can plug it into a generator or power station.
  • Never back-feed the house through a wall or dryer outlet with a double-ended cord. It can electrocute line workers and start fires.
  • Heat pumps and electric heat need 240 V circuits and a standby generator or home battery system sized for them (size one in the Whole-Home Backup Sizer); that’s a job for an electrician and, for gas, a plumber.

Work out your own list in the Outage Plan Builder: start with the gas furnace version, the electric heat version, or build your own.

Sources

Questions people ask

How do I keep my house warm when the power goes out?

If you have a gas or propane furnace or boiler, it only needs a little electricity for its blower or pump, so a power station or small generator on a transfer switch can keep it running. If your heat is electric or a heat pump, backup power for it means a large standby generator or home batteries, so most people heat one room, close it off, dress in layers and use electric blankets instead. Never heat the house with a gas oven, grill or camp stove.

Will a gas furnace work without electricity?

No. A gas furnace burns gas for heat, but the blower, the igniter, the draft inducer and the control board all need electricity. A standard furnace uses about 6 kWh a day in winter, so a 1,000 Wh power station runs it for about 3 hours, and a small inverter generator for about 2.7 gal of gas a day along with a fridge and lights.

Can a generator run a heat pump?

Only a big one. A 3-ton heat pump needs 240 V and starts with a surge of about 15,000 W, more than any portable generator in our data covers. With its electric backup strips on it draws about 12,500 W. Heat pump homes usually need a standby generator or home batteries, or they lock out the strips and accept a cooler house.

Can a power station run a space heater in a power outage?

Only briefly. A 1,500 W heater on high empties a 1,000 Wh station in about 0.5 hours, and about 1.1 hours if it cycles on a thermostat. Electric blankets use a small fraction of that energy and are the better use of a battery.

How do I keep pipes from freezing when the power is out?

Let a trickle of water run from faucets on outside walls, open the cabinet doors under sinks, and keep the warmest room's doors closed. If the house will be without heat for days in deep cold, shut off the main water valve and drain the pipes, or ask a plumber to. Never thaw a pipe with an open flame.