How Much Gas Does a Generator Use? Per Hour, per Tank, per Day

Gas use per hour, hours per tank and gallons a day for 13 portable generators at light, half and full load, plus what a typical outage day really burns.

Updated

How we make money: some links on this page go to stores that may pay us a commission if you buy. It doesn't change the price you pay or which product we recommend; we rank by fit first. Details

The short answer: a small inverter generator uses about 0.10 to 0.20 gallons of gas an hour at light load, and about 0.23 to 0.49 at full load. A big conventional generator uses about 0.54 to 0.63 gallons an hour even when it’s barely loaded. Over a day of running a fridge, sump pump, furnace fan, lights and internet, that’s about 3 gallons for a 3,000 W inverter generator and 6 to 13 gallons for a conventional one.

The type and size of the generator matter more than what you plug into it.

Gas per hour, by generator and load

From the makers’ runtime claims where they publish them, worked through our fuel model. “Light” is a quarter of the generator’s running watts, “half” is half, and “full” is its full rating.

GeneratorRunning wattsLight (gal/h)Half (gal/h)Full (gal/h)
Honda EU2200i (inverter)1,800 W0.120.180.30
Westinghouse iGen2800 (inverter)2,200 W0.100.140.23
Honda EU3200i (inverter)2,600 W0.140.220.37
Generac iQ3500 (inverter)3,000 W0.200.300.49
Generac iQ3800 (inverter)3,000 W0.170.260.43
Westinghouse WGen3600 (conventional)*3,600 W0.280.360.51
Westinghouse WGen5300 (conventional)*5,300 W0.410.520.75
Honda EU7000iS (inverter)5,500 W0.320.480.80
Generac GP6500 (conventional)6,500 W0.540.690.99
Westinghouse iGen8200 (inverter)6,600 W0.230.350.58
Generac GP8000E (conventional)8,000 W0.630.791.13
Westinghouse iGen12000 (inverter)9,000 W0.420.631.04
Generac GP9500E (conventional)9,500 W0.540.891.58

* The maker publishes no runtime figures for the Westinghouse WGen3600 and Westinghouse WGen5300, so they’re estimated from typical generators. The Honda EU2200i, Honda EU3200i, Generac iQ3800, Honda EU7000iS and Generac GP9500E have two maker figures each, so their lines are fitted to the maker’s own numbers; the rest have one maker figure and our typical curve shape. Rates are rounded up.

Hours per tank

GeneratorTankLightHalfFull
Honda EU2200i0.95 gal8 h5 h3 h
Westinghouse iGen28001.1 gal12 h8 h4.5 h
Honda EU3200i1.2 gal8.5 h5.5 h3 h
Generac iQ35002.6 gal13 h8.5 h5 h
Generac iQ38003.28 gal20 h13 h7.5 h
Westinghouse WGen3600*4 gal14 h11 h7.5 h
Westinghouse WGen5300*4.7 gal11.5 h9 h6 h
Honda EU7000iS5.1 gal16 h10.5 h6 h
Generac GP65007.9 gal14.5 h11.5 h8 h
Westinghouse iGen82003.9 gal17 h11 h6.5 h
Generac GP8000E7.9 gal12.5 h10 h7 h
Westinghouse iGen120007.9 gal19 h12.5 h7.5 h
Generac GP9500E7.5 gal14 h8.5 h4.5 h

Rounded down. Plan to refuel at least once a day with almost any of them, and twice or more with the small Hondas.

What a real outage day burns

Generators rarely run near full load in an outage. A typical “essentials” list (a fridge, a ⅓ HP sump pump in moderate rain, a furnace fan, five LED bulbs, a router and modem, a TV and two phone chargers) averages about 384 W over a day, because the fridge and pump cycle on and off.

GeneratorGas a day (24 h)Hours per tank
Honda EU3200i2.7 gal11 h
Generac iQ38003 gal27 h
Generac iQ35003.6 gal17.5 h
Westinghouse iGen82003.9 gal24 h
Honda EU7000iS5.4 gal22.5 h
Westinghouse WGen3600*5.7 gal17 h
Westinghouse iGen120007 gal27 h
Generac GP9500E7.9 gal22.5 h
Westinghouse WGen5300*8.2 gal13.5 h
Generac GP650010.9 gal17.5 h
Generac GP8000E12.5 gal15 h

The Honda EU2200i and Westinghouse iGen2800 can’t start this list (the sump pump and furnace blower together need about 2,900 starting watts). Without the pump and furnace, a fridge, lights, internet and TV, they use about **2** and **1.6** gallons a day.

For a 3-day outage, that’s about 9 to 11 gallons for a 3,000 W inverter generator and 17 to 38 gallons for a conventional one. Store it in approved containers, outside the house.

Why inverter generators use so much less

A conventional generator’s engine runs at full speed all the time to hold 60 Hz, so it burns a lot of fuel even with little plugged in: in our model about 40% of its full-load rate at no load. An inverter generator throttles its engine down to match the load, to about 20%. At outage-type loads that’s the whole difference: the iQ3800 and the WGen3600 are a similar size, but the inverter one uses about half the gas.

A bigger generator also burns more at light load than a smaller one. Our model never counts less than 10% of the rating, because no engine idles on nothing. Don’t buy more generator than your running and starting watts call for.

Work out your own generator’s gas use

Most makers publish a runtime claim, such as “8.1 hours at 25% load” on the Honda EU2200i’s 0.95-gallon tank. Turn it into a rate:

gas an hour = tank gallons ÷ hours = 0.95 ÷ 8.1 = 0.117 gal/h at a quarter load

With a second claim (Honda’s 3.2 hours at full load, 0.30 gal/h), you can draw a straight line between the two and read off any load in between. That’s what our Generator Size & Fuel Calculator does, with your own appliances, hours a day and outage length.

Ways to use less gas

  • Run it in shifts. A fridge keeps food safe for up to 4 hours closed, and a full freezer for about 48 (USDA). Running the generator 12 hours a day instead of 24 can roughly halve the fuel. See battery backup for a refrigerator.
  • Pair it with a power station. Run the generator for a few hours to cool the fridge and recharge the station, then switch it off and let the station carry the quiet loads overnight.
  • Use an eco or economy mode on an inverter generator; turn it off when you need big starting surges.
  • Keep stored gas fresh. Untreated gasoline goes stale over a few months. Add fuel stabilizer to stored gas and rotate it.

On propane instead? See how long a generator runs on a propane tank.

Inverter or conventional? Inverter generator vs regular generator compares same-size models on gas a day, side by side.

Products in this guide

Honda EU3200i

Running / starting
2,600 / 3,200 W (gasoline)
Type
Inverter (clean power)
Fuels
gasoline
CO shutoff
Yes
Weight
59.1 lb
Check price at Honda

Usually about $2,799 on the Honda site. Specs checked Nov 17, 2026.

Generac iQ3800 Dual Fuel

Running / starting
3,000 / 3,800 W (gasoline)
Type
Inverter (clean power)
Fuels
gasoline, propane
CO shutoff
Yes
Weight
107 lb
Check price at Generac

Usually about $1,029 on the Generac site. Specs checked Nov 19, 2026.

Westinghouse WGen3600DFv

Running / starting
3,600 / 4,650 W (gasoline)
Type
Conventional
Fuels
gasoline, propane
CO shutoff
No
Check price at Westinghouse

Usually about $499 on the Westinghouse site. Specs checked Nov 17, 2026.

Questions people ask

How much gas does a generator use per hour?

A small inverter generator (2,000 to 3,500 W) uses about 0.10 to 0.20 gallons an hour at light load and 0.23 to 0.49 at full load. A 6,500 to 9,500 W conventional generator uses about 0.54 to 0.63 gallons an hour even at light load, and 0.99 to 1.58 at full load.

How much gas does a generator use in 24 hours?

Running a fridge, a sump pump, a furnace fan, lights and internet, a 3,000 W inverter generator uses about 3 gallons a day. A 3,600 W conventional generator uses about 5.7 gallons for the same load, and a 6,500 W conventional generator about 10.9 gallons.

How long will a generator run on a tank of gas?

It depends mostly on the tank and the load. At a quarter load, a Honda EU2200i runs about 8 hours on its 0.95-gallon tank, a Generac iQ3800 about 20 hours on 3.28 gallons, and a Generac GP6500 about 14.5 hours on 7.9 gallons. At full load, most run 3 to 8 hours.

How long will a generator run on 5 gallons of gas?

At a quarter load, about 30 hours for a 3,000 W inverter generator such as the Generac iQ3800, about 18 hours for a 3,600 W conventional generator, and about 9 hours for a 6,500 W conventional generator.

Can a generator run for 24 hours?

Yes, if you refuel it. Turn it off and let it cool before every refill, and check the oil as often as the manual says. Many people run it a few hours at a time instead, which saves a lot of fuel.