Inverter Generator vs Regular Generator: Gas, Noise and Cost
Inverter and conventional generators of the same size compared on gas a day, hours per tank, noise, clean power, 240 V and price per watt.
Updated
How we make money: some links on this page go to stores that may pay us a commission if you buy. It doesn't change the price you pay or which product we recommend; we rank by fit first. Details
Open the Generator Size & Fuel Calculator
The short answer: an inverter generator is quieter, uses less gas and gives cleaner power; a regular (conventional) generator costs much less per watt. For a fridge, sump pump, furnace fan and lights, an inverter generator in the 2,000 to 3,500 W range is usually the better buy. For 240 V and a whole-house transfer switch on a budget, a conventional generator is hard to beat. Every figure below comes from the makers’ specs and our fuel model.
How they make power
A conventional generator spins its engine at a fixed 3,600 rpm, because that speed is what makes 60 Hz power. It runs flat out whether you’re powering a phone charger or a well pump, so at no load it still burns about 40% of its full-load fuel. An inverter generator turns the alternator’s output into DC and electronics rebuild it as a clean 60 Hz sine wave. Because the frequency no longer depends on engine speed, the engine slows down at light load (“eco” mode) and burns about 20% of its full-load fuel at idle. The same electronics keep distortion low (the makers that publish it quote about 3% THD), which matters for some appliances.
Same size, side by side
Each pair is an inverter and a conventional generator of about the same running watts. “Gas a day” is running around the clock with a fridge, chest freezer, ⅓ HP sump pump, furnace fan, 8 LED bulbs, TV and internet on: an average of 416 W, needing a 2,200 / 3,050 W generator. Prices are the brand’s own, checked in November 2026.
| Generator | Type | Running / starting | Brand price | Per running watt | Gas a day | Tank (hours at ¼ load) | 240 V | CO shutoff |
|---|---|---|---|---|---|---|---|---|
| 3,000–3,600 W | ||||||||
| Generac iQ3500 | Inverter | 3,000 / 3,500 W | $1,049 | $0.35 | 3.7 gal | 2.6 gal (13 h) | no | yes |
| Westinghouse WGen3600 | Conventional | 3,600 / 4,650 W | $499 | $0.14 | 5.7 gal | 4 gal (14 h) | no | no |
| 5,300–5,500 W | ||||||||
| Honda EU7000iS | Inverter | 5,500 / 7,000 W | $4,899 | $0.89 | 5.4 gal | 5.1 gal (16 h) | yes | yes |
| Westinghouse WGen5300 | Conventional | 5,300 / 6,500 W | $759 | $0.14 | 8.2 gal | 4.7 gal (11.5 h) | yes | no |
| 6,500–6,600 W | ||||||||
| Westinghouse iGen8200 | Inverter | 6,600 / 8,200 W | $1,599 | $0.24 | 3.9 gal | 3.9 gal (17 h) | yes | yes |
| Generac GP6500 | Conventional | 6,500 / 8,125 W | $939 | $0.14 | 10.9 gal | 7.9 gal (14.5 h) | yes | yes |
| 9,000–9,500 W | ||||||||
| Westinghouse iGen12000 | Inverter | 9,000 / 12,000 W | $2,199 | $0.24 | 7 gal | 7.9 gal (19 h) | yes | yes |
| Generac GP9500E | Conventional | 9,500 / 12,500 W | $1,289 | $0.14 | 7.9 gal | 7.5 gal (14 h) | yes | yes |
In every pair the inverter generator uses less gas and costs more. The gap is widest between the Westinghouse iGen8200 and the Generac GP6500: 3.9 gal against 10.9 gal a day for the same load. Neither of the 3,000 W-class pair has a 240 V outlet; from the 5,000 W class up, both kinds do. Every inverter model here, and the Generac conventional ones, has a carbon monoxide shutoff.
Gas at light, half and full load
Gallons an hour at a quarter, half and full load of each generator’s own running watts, rounded up. “Saves” is how much less the inverter uses than its partner at a quarter load, which is where a generator on a household list spends most of its time.
| Generator | ¼ load | ½ load | Full load | Saves at ¼ load |
|---|---|---|---|---|
| Generac iQ3500 (inverter) | 0.20 | 0.30 | 0.49 | 30% |
| Westinghouse WGen3600 (conventional)* | 0.28 | 0.36 | 0.51 | |
| Honda EU7000iS (inverter) | 0.32 | 0.48 | 0.80 | 22% |
| Westinghouse WGen5300 (conventional)* | 0.41 | 0.52 | 0.75 | |
| Westinghouse iGen8200 (inverter) | 0.23 | 0.35 | 0.58 | 57% |
| Generac GP6500 (conventional) | 0.54 | 0.69 | 0.99 | |
| Westinghouse iGen12000 (inverter) | 0.42 | 0.63 | 1.04 | 22% |
| Generac GP9500E (conventional) | 0.54 | 0.89 | 1.58 |
*No runtime figures from the maker, so worked out from typical generators of its type. The rest use the maker’s runtime claims. At a quarter load the inverter saves 22% to 57%. At full load both engines run flat out, so the gap is smaller in most pairs. The gas use guide has hours per tank and more generators.
Noise and weight
Makers measure noise differently (distance, load), so treat these as rough. Only 5 of the portable generators we track publish a noise figure, and all of them are inverter models; none of the conventional ones do.
| Generator | Noise | THD | Weight |
|---|---|---|---|
| Honda EU2200i (inverter) | 57 dBA | — | 47 lb |
| Westinghouse iGen2800 (inverter) | 52 dBA | 3% | 45 lb |
| Honda EU3200i (inverter) | 58 dBA | — | 59 lb |
| Honda EU7000iS (inverter) | 58 dBA | — | 263 lb |
| Westinghouse iGen8200 (inverter) | — | 3% | — |
| Westinghouse iGen12000 (inverter) | 64 dBA | 3% | — |
“—” means the maker doesn’t publish it. The quietest here is the Westinghouse iGen2800 (52 dBA) and the loudest the Westinghouse iGen12000 (64 dBA). An open-frame conventional generator at its fixed engine speed is usually louder still, and much louder than an inverter generator in eco mode at night. Neighbors notice.
Clean power: which appliances care
Most things don’t mind: a fridge, a sump pump, a standard furnace fan, lights and phone chargers all run fine on a conventional generator. Appliances in our data that want a clean sine wave are: Furnace fan (ECM), Boiler, Pellet stove, Mini-split, Desktop PC, CPAP, CPAP + humidifier, BiPAP. With one of those on the list, our generator calculator only suggests inverter generators, or a conventional one whose maker states under 6% total harmonic distortion. None of the conventional generators we track publish that figure, so the Westinghouse WGen3600, Westinghouse WGen5300, Generac GP6500, Generac GP8000E and Generac GP9500E drop out once a variable-speed furnace blower is added to the household list above.
Cost over a 3-day outage
The inverter costs more up front; the conventional generator costs more in gas. Running the household list around the clock for three days:
| Size | Inverter: price, gas for 3 days | Conventional: price, gas for 3 days | Extra gas, conventional | Extra price, inverter |
|---|---|---|---|---|
| 3,000–3,600 W | Generac iQ3500: $1,049, 10.9 gal | Westinghouse WGen3600: $499, 17.1 gal | 6.2 gal | $550 |
| 5,300–5,500 W | Honda EU7000iS: $4,899, 16.1 gal | Westinghouse WGen5300: $759, 24.6 gal | 8.5 gal | $4,140 |
| 6,500–6,600 W | Westinghouse iGen8200: $1,599, 11.6 gal | Generac GP6500: $939, 32.6 gal | 21 gal | $660 |
| 9,000–9,500 W | Westinghouse iGen12000: $2,199, 21 gal | Generac GP9500E: $1,289, 23.6 gal | 2.6 gal | $910 |
Multiply the extra gallons by your local gas price to see how many outages it takes to pay back. Gas is also something you have to buy, store and pour during an outage: the Generac GP6500 needs 21 gallons more than the Westinghouse iGen8200 over three days, which is several extra trips with cans. Running the generator a few hours at a time instead of all day cuts both.
Which one fits you
The matching generators in our data for four household lists, smallest first and then lowest price per watt (the same order the Generator Size & Fuel Calculator uses; we never rank by commission).
| What you’ll run | Generator to look for | Matches (price per running watt) |
|---|---|---|
| Fridge, 4 LED bulbs, internet and 2 phone chargers | 350 / 1,100 W | Honda EU2200i, inverter ($0.67); Westinghouse iGen2800, inverter ($0.27); Honda EU3200i, inverter ($1.08) |
| The household list above (fridge, freezer, sump pump, furnace fan, lights, TV, internet) | 2,200 / 3,050 W | Honda EU3200i, inverter ($1.08); Generac iQ3800, inverter ($0.34); Generac iQ3500, inverter ($0.35) |
| The same list with a variable-speed (ECM) furnace blower | 1,900 / 2,800 W | Westinghouse iGen2800, inverter ($0.27); Honda EU3200i, inverter ($1.08); Generac iQ3800, inverter ($0.34) |
| The household list plus a ½ HP 240 V well pump | 3,200 / 5,150 W | Westinghouse WGen5300, conventional ($0.14); Honda EU7000iS, inverter ($0.89); Generac GP6500, conventional ($0.14) |
- A fridge, lights and internet, or camping too: a small inverter generator such as the Honda EU2200i. It’s light, quiet and sips gas.
- The house essentials, or a furnace with a variable-speed blower: a 3,000 W-class inverter generator. A conventional 3,600 W model costs less but uses more gas a day and isn’t suitable for the ECM blower.
- A 240 V well pump, or a whole-house transfer switch: you need 3,200 / 5,150 W and a 240 V outlet. The Westinghouse WGen5300 is the least expensive match; a 240 V inverter model costs much more but saves gas. See what size generator for a house.
Still deciding between a generator and a battery? See power station vs generator.
Work out your own
Put your own appliances into the Generator Size & Fuel Calculator: it finds the running and starting watts you need, checks 240 V and clean power, and shows gas a day for each match. The Outage Plan Builder compares a generator with a power station for the whole outage.
Related
Products in this guide
Honda EU2200i
- Running / starting
- 1,800 / 2,200 W (gasoline)
- Type
- Inverter (clean power)
- Fuels
- gasoline
- CO shutoff
- Yes
- Weight
- 47.4 lb
Usually about $1,199 on the Honda site. Specs checked Nov 17, 2026.
Generac iQ3500
- Running / starting
- 3,000 / 3,500 W (gasoline)
- Type
- Inverter (clean power)
- Fuels
- gasoline
- CO shutoff
- Yes
- Weight
- 109.1 lb
Usually about $1,049 on the Generac site. Specs checked Nov 17, 2026.
Westinghouse WGen3600DFv
- Running / starting
- 3,600 / 4,650 W (gasoline)
- Type
- Conventional
- Fuels
- gasoline, propane
- CO shutoff
- No
Usually about $499 on the Westinghouse site. Specs checked Nov 17, 2026.
Westinghouse iGen8200TFc
- Running / starting
- 6,600 / 8,200 W (gasoline)
- Type
- Inverter (clean power)
- Fuels
- gasoline
- CO shutoff
- Yes
Usually about $1,599 on the Westinghouse site. Specs checked Nov 17, 2026.
Generac GP6500 COsense
- Running / starting
- 6,500 / 8,125 W (gasoline)
- Type
- Conventional
- Fuels
- gasoline
- CO shutoff
- Yes
- Weight
- 172 lb
Usually about $939 on the Generac site. Specs checked Nov 17, 2026.
Westinghouse WGen5300DFv
- Running / starting
- 5,300 / 6,500 W (gasoline)
- Type
- Conventional
- Fuels
- gasoline, propane
- CO shutoff
- No
Usually about $759 on the Westinghouse site. Specs checked Nov 17, 2026.
Questions people ask
What is the difference between an inverter generator and a regular generator?
A regular (conventional) generator runs its engine at a fixed speed to make 60 Hz power directly. An inverter generator turns its output into DC and back into a clean 60 Hz sine wave, so its engine can slow down when the load is light. That makes it quieter and thriftier: running the same fridge, freezer, sump pump, furnace fan and lights all day, a Westinghouse iGen8200 uses about 3.9 gal of gas and a Generac GP6500 about 10.9 gal.
Is an inverter generator better than a regular generator?
For most home backup, yes, if it's big enough: it uses less gas, it's quieter, and its power suits electronics. A conventional generator costs less per watt (a median of $0.14 per running watt in our data, against $0.35 for inverter models), and it's the cheaper way to get the 240 V a well pump or a transfer switch needs.
Do inverter generators use less gas?
Yes, most of all at light loads, where a generator spends much of an outage. At a quarter load a Generac iQ3500 uses about 0.20 gallons an hour and a similar-size Westinghouse WGen3600 about 0.28. Across the four same-size pairs we compare, the inverter uses 22% to 57% less gas at a quarter load.
Can a regular generator run a furnace or a CPAP?
Often it can, but its power can be rougher, and none of the conventional generators we track publish a distortion (THD) figure. A variable-speed (ECM) furnace blower, boiler controls, a CPAP or a desktop PC want clean power, so for those we only suggest inverter generators, or a conventional one whose maker states under 6% THD.
Is an inverter generator worth it for home backup?
Usually, in the 2,000 to 3,500 W size that runs a fridge, sump pump, furnace fan and lights, where it costs a few hundred dollars more and saves gas every day. Bigger ones cost far more: the brand price is $4,899 for a Honda EU7000iS and $759 for a Westinghouse WGen5300, both with 240 V. If you need 240 V on a budget, a conventional generator is the practical choice.