Outage Plan Builder
Choose a scenario and tell us about your home. Edit the list of what you'll keep running, then compare a power station, a generator, and a power station you refill each day, with products that fit.
How we make money: some links on this page go to stores that may pay us a commission if you buy. It doesn't change the price you pay or which product we recommend; we rank by fit first. Details
What your list needs
- Running at once (peak)
- 2,784 W
- Starting surge (peak)
- 3,634 W (when the Fridge starts)
- Average over a day
- 139 W
Show the math
- Fridge: average draw: 500 kWh a year × 1,000 ÷ 8,760 h (Energy Star label) = 57.1 W
- LED bulb: average draw: 9 W × 4 = 36 W
- Router: average draw: 10 W = 10 W
- Modem: average draw: 8 W = 8 W
- Phone: average draw: 20 W × 2 = 40 W
- Microwave: average draw: 1,400 W = 1,400 W
- Coffee maker: average draw: 1,000 W = 1,000 W
- TV: average draw: 80 W = 80 W
- Laptop: average draw: 60 W = 60 W
- Energy a day: 57.1 W × 24 h + 36 W × 5 h + 10 W × 24 h + 8 W × 24 h + 40 W × 2 h + 1,400 W × 0.3 h + 1,000 W × 0.3 h + 80 W × 4 h + 60 W × 6 h = 3,342 Wh
- Average over the day: 3,342 Wh ÷ 24 h = 139.2 W
- Peak running watts: 150 W + 9 W × 4 + 10 W + 8 W + 20 W × 2 + 1,400 W + 1,000 W + 80 W + 60 W = 2,784 W
- Peak starting watts: 2,784 W + 850 W extra while the Fridge starts (one motor starts at a time) = 3,634 W
A. Power station only
Silent, safe indoors, no fuel. It has to hold the whole outage, so long outages get big and expensive.
These cover 3 days of your list, with a 25% margin:
Jackery HomePower 3600 Plus + 5 × Jackery Battery Pack 3600 Plus
21,504 Wh · 3,600 W continuous
Anker SOLIX F3800 Plus + 5 × Anker SOLIX BP3800 Expansion Battery
23,040 Wh · 6,000 W continuous · 240 V
Jackery Explorer 5000 Plus + 4 × Jackery Battery Pack 5000 Plus
25,200 Wh · 7,200 W continuous · 240 V
B. Generator
Cheapest for long outages, but loud and it needs fuel and someone to run it. Outdoors only, at least 20 feet from the house: see generator safety.
Look for at least 3,500 W running and 3,650 W starting watts.
Westinghouse WGen3600DFv
3,600 W running · conventional
Run all day: about 5.6 gal a day, 16.7 gal over 3 days
Westinghouse WGen5300DFv
5,300 W running · conventional
Honda EU7000iS
5,500 W running · inverter (quieter, clean power) · 58 dBA · CO shutoff
- Fuel use is estimated from typical generators; this model's maker publishes no runtime figures.
Show the math
- Peak running watts: 150 W + 9 W × 4 + 10 W + 8 W + 20 W × 2 + 1,400 W + 1,000 W + 80 W + 60 W = 2,784 W
- Peak starting watts: 2,784 W + 850 W extra while the Fridge starts (one motor starts at a time) = 3,634 W
- Running watts needed: 2,784 W ÷ 0.8 (keep it under 80% load) = 3,480 W
- Fridge: average draw: 500 kWh a year × 1,000 ÷ 8,760 h (Energy Star label) = 57.1 W
- LED bulb: average draw: 9 W × 4 = 36 W
- Router: average draw: 10 W = 10 W
- Modem: average draw: 8 W = 8 W
- Phone: average draw: 20 W × 2 = 40 W
- Microwave: average draw: 1,400 W = 1,400 W
- Coffee maker: average draw: 1,000 W = 1,000 W
- TV: average draw: 80 W = 80 W
- Laptop: average draw: 60 W = 60 W
- Energy while it runs: 57.1 W × 24 h + 36 W × 5 h + 10 W × 24 h + 8 W × 24 h + 40 W × 2 h + 1,400 W × 0.3 h + 1,000 W × 0.3 h + 80 W × 4 h + 60 W × 6 h = 3,342 Wh
- Average load on the generator: 3,342 Wh ÷ 24 h = 139 W
- Full-load rate (typical generators): 3.6 kW × 0.14 gal/h per kW = 0.504 gal/h
- Load fraction: 139 W ÷ 3,600 W (held between 10% and 100%) = 0.1
- Fuel an hour: 0.504 × (0.4 + 0.6 × 0.1) = 0.232 gal/h
- Hours per tank: 4 gal ÷ 0.232 gal/h = 17.25 h
- Fuel a day: 0.232 gal/h × 24 h = 5.56 gal
- Fuel for the outage: 5.56 gal × 3 days = 16.69 gal
Assumptions used: Generator load limit; Fallback gas use, conventional generator; No-load fuel use, conventional generator. What these mean
C. Hybrid: a power station you refill each day
A station big enough for one day of your list, about 4,577 Wh from its battery, refilled by solar panels or by a small generator for a few hours a day. Quiet most of the day, with far less fuel.
EcoFlow DELTA 3 Ultra + 1 × EcoFlow DELTA Pro 3 Smart Extra Battery
7,168 Wh · 3,600 W continuous
With solar panels
It would take about 1,400 W of panels, but this station takes only 800 W of solar: that covers about 59% of a day, so the battery still runs down. Add generator charging on cloudy days. Panels are extra; the solar recharge calculator works out charging times.
Show the math
- Panel watts to cover a day: 4,577 Wh ÷ (0.75 × 4.5 sun hours) = 1,356 W
- Share of a day the most panels cover: 800 W × 0.75 × 4.5 h ÷ 4,577 Wh = 59%
Assumptions used: Solar system losses. What these mean
With a small generator for charging
Charging at about 1,800 W, run a generator about 3 hours a day. On a Honda EU3200i, that's about 2.4 gal over 3 days.
Honda EU3200i
2,600 W running · inverter (quieter, clean power) · 58 dBA · CO shutoff
Show the math
- Station charging watts: EcoFlow DELTA 3 Ultra maximum AC input = 1,800 W
- Generator hours a day: 4,577 Wh ÷ (1,800 W × 0.9) = 2.83 h
- Fuel curve from the maker’s claims: 0.14 gal/h at 25% load; 0.364 gal/h at 100% load = 0.065 + 0.299 × load gal/h
- Load fraction: 1,800 W ÷ 2,600 W = 0.692
- Fuel an hour: 0.065 + 0.299 × 0.692 = 0.272 gal/h
- Hours per tank: 1.2 gal ÷ 0.272 gal/h = 4.42 h
- Fuel a day: 0.272 gal/h × 2.8 h = 0.77 gal
- Fuel for the outage: 0.77 gal × 3 days = 2.3 gal
Assumptions used: Power station charging efficiency. What these mean
Product prices are list prices we last checked; links marked "Check price" are affiliate links. Ranking uses fit, size and price per watt-hour or watt only.
How this is calculated
What your list needs
Energy a day adds up each appliance's watts × the hours it runs, using its duty cycle (a fridge compressor only runs part of the time) or its Energy Star kWh a year where we have one. The range uses every appliance's low and high draw. Peak running watts are everything on at once; the starting surge adds the biggest single motor start, assuming you start big motors one at a time.
A. Power station only
We count on 95% of a station's rated Wh. AC appliances go through its inverter, which delivers about 90% of what it takes from the battery and draws a few watts just by being on. A station has to run everything on the list at once and start the biggest motor, and hold the whole outage with a 25% margin, adding extra batteries where our data has a compatible one.
B. Generator
The generator's running watts must cover your peak with the load kept under 80% of its rating, and its starting watts must cover the surge. Fuel assumes it runs all day, every day, at your list's average load, using a fuel curve fitted to the maker's runtime claims where they publish them.
C. Hybrid
We pick the smallest station that covers one day of your list. Solar panels needed = Wh a day ÷ (0.75 × peak sun hours); 0.75 covers heat, angle, dirt and charging losses, and we check the station's solar input limit. Generator hours a day = Wh a day ÷ (the station's AC charging watts × 0.9), where 0.9 is the share of charging power that ends up stored. The charging generator is the smallest one that supplies those watts with 80% headroom.
How we pick products
Only current models that pass every check. Power stations: fits on its own before needing an extra battery, then the smallest that's enough, then the lowest price per usable Wh. Generators: the smallest that fits, then the lowest price per running watt. Commissions and affiliate programs play no part.
What we don't know yet
Inverter idle draw (5 W or 1% of a station's rating) and charging efficiency are first estimates we'll check with our own meter, and many appliance figures are estimates (marked in the list). Big stations look worse than they may be for small loads because the idle draw runs all day.
Full formulas and default assumptions: How the math works.
Related
- Solar Recharge Calculator (how long panels take to refill a station or battery)
- Power Station Runtime Calculator (one station, your list, solar what-ifs)
- Generator Size & Fuel Calculator
- CPAP Battery Backup Calculator (nights, with the 2× medical planning rule)
- Sump Pump Backup Calculator
- What size generator do I need for my house?
- Power station vs generator: which is better for an outage?
- Inverter generator vs regular generator: gas, noise and cost
- Whole-Home Backup Sizer (standby generator or home batteries for the whole house)
- Battery backup for a refrigerator
- How to keep heat on in a winter power outage (every heating type, with this builder's winter lists)
- Battery backup for a gas furnace
- Generator safety: carbon monoxide, rain, cords and transfer switches
- Safety and medical notes
Questions people ask
What should I keep running in a power outage?
Start with what protects health, food and the house: medical devices, the fridge and freezer, heat in winter (a gas furnace needs power for its blower), a sump or well pump, then lights, phones and internet. Cooking, TV and air conditioning come after that, because each one adds a lot to what you need.
Is a generator or a power station better for a power outage?
A power station is silent, safe indoors and needs no fuel, but it has to store everything you use, so long outages get expensive. A generator is the cheapest way to run a lot for days, but it is loud, needs fuel, and must run outdoors at least 20 feet from the house. A mid-size power station topped up by solar or a small generator a few hours a day sits in between.
How big a power station do I need for a 3-day outage?
For a fridge, four LED bulbs, internet and two phone chargers (about 2,062 Wh a day), we'd look at a Jackery HomePower 3600 Plus with 3 extra batteries: about 14,336 Wh. A 4,096 Wh station recharged by a generator for about 2 hours a day, or by solar panels, does the same job for less.
How much gas do I need for a 3-day outage?
It depends on the generator and what it runs. The same fridge-and-essentials list on a Honda EU2200i running all day uses about 2 gal a day, 5.9 gal over three days. Bigger loads and conventional generators use more. Store gas in approved cans with stabilizer.